Part Number | Manu. | Model | Offer Price | |||||||
Wolf special offer - Tube furnace Carbolite TF1 12/60/300 with 1 zone not split, temperature range 400 to 1200°C, heated tube length 300mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately OFFER ENDS 31-07-2025 ![]() |
*Popular*TF1120600300-230SN
Wolf special offer - Tube furnace Carbolite TF1 12/60/300 with 1 zone not split, temperature range 400 to 1200°C, heated tube length 300mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately OFFER ENDS 31-07-2025 |
Carbolite | TF112/60/300 | 1 | No | 400 | 1200 | 300 | 60 | £4273.00 |
Wolf special offer - Tube furnace Carbolite TF3 12/60/450 with 3 zones not split, temperature range 400 to 1200°C, heated tube length 450mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, touch screen and remote control, requires work tube to be purchased separately OFFER ENDS 31-07-2025 ![]() |
*Offer*TF3120600450-230SN
Wolf special offer - Tube furnace Carbolite TF3 12/60/450 with 3 zones not split, temperature range 400 to 1200°C, heated tube length 450mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, touch screen and remote control, requires work tube to be purchased separately OFFER ENDS 31-07-2025 |
Carbolite | TF312/60/450 | 3 | No | 400 | 1200 | 450 | 60 | £7607.00 |
Wolf special offer - Tube furnace Carbolite TF1 16/60/300 with 1 zone not split, temperature range 600 to 1600°C, heated tube length 300mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 25Amps, no touch screen, with remote control, requires work tube to be pruchased separately OFFER ENDS 31-07-2025 ![]() |
*Offer*TF1160600300-230SN
Wolf special offer - Tube furnace Carbolite TF1 16/60/300 with 1 zone not split, temperature range 600 to 1600°C, heated tube length 300mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 25Amps, no touch screen, with remote control, requires work tube to be pruchased separately OFFER ENDS 31-07-2025 |
Carbolite | TF116/60/300 | 1 | No | 600 | 1600 | 300 | 60 | £9694.00 |
Wolf special offer - Tube furnace Carbolite TF3 16/100/450 with 3 zones not split, temperature range 600 to 1600°C, heated tube length 450mm, can accommodate tubes up to 100mm diameter, single phase, 230volts, 50Amps, touch screen and remote control, requires work tube to be pruchased separately OFFER ENDS 31-07-2025 ![]() |
*Offer*TF3161000450-230SN
Wolf special offer - Tube furnace Carbolite TF3 16/100/450 with 3 zones not split, temperature range 600 to 1600°C, heated tube length 450mm, can accommodate tubes up to 100mm diameter, single phase, 230volts, 50Amps, touch screen and remote control, requires work tube to be pruchased separately OFFER ENDS 31-07-2025 |
Carbolite | TF316/100/450 | 3 | No | 600 | 1600 | 450 | 100 | £15872.00 |
Tube furnace Carbolite TF1 11/32/150 with 1 zone not split, temperature range 400 to 1100°C, heated tube length 150mm, can accommodate tubes up to 32mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TF1110320150-230SN
Tube furnace Carbolite TF1 11/32/150 with 1 zone not split, temperature range 400 to 1100°C, heated tube length 150mm, can accommodate tubes up to 32mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TF111/32/150 | 1 | No | 400 | 1100 | 150 | 32 | £3065.00 |
Tube furnace Carbolite TF1 12/60/150 with 1 zone not split, temperature range 400 to 1200°C, heated tube length 150mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TF1120600150-230SN
Tube furnace Carbolite TF1 12/60/150 with 1 zone not split, temperature range 400 to 1200°C, heated tube length 150mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TF112/60/150 | 1 | No | 400 | 1200 | 150 | 60 | £4132.00 |
Tube furnace Carbolite TF1 12/60/450 with 1 zone not split, temperature range 400 to 1200°C, heated tube length 450mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TF1120600450-230SN
Tube furnace Carbolite TF1 12/60/450 with 1 zone not split, temperature range 400 to 1200°C, heated tube length 450mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TF112/60/450 | 1 | No | 400 | 1200 | 450 | 60 | £5166.00 |
Tube furnace Carbolite TF1 12/60/600 with 1 zone not split, temperature range 400 to 1200°C, heated tube length 600mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TF1120600600-230SN
Tube furnace Carbolite TF1 12/60/600 with 1 zone not split, temperature range 400 to 1200°C, heated tube length 600mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TF112/60/600 | 1 | No | 400 | 1200 | 600 | 60 | £5674.00 |
Tube furnace Carbolite TF1 12/125/400 with 1 zone not split, temperature range 400 to 1200°C, heated tube length 400mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TF1121250400-230SN
Tube furnace Carbolite TF1 12/125/400 with 1 zone not split, temperature range 400 to 1200°C, heated tube length 400mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TF112/125/400 | 1 | No | 400 | 1200 | 400 | 125 | £6060.00 |
Tube furnace Carbolite TS1 12/60/150 split tube with 1 zone, temperature range 400 to 1200°C, heated tube length 150mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TS1120600150-230SN
Tube furnace Carbolite TS1 12/60/150 split tube with 1 zone, temperature range 400 to 1200°C, heated tube length 150mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TS112/60/150 | 1 | Yes | 400 | 1200 | 150 | 60 | £6507.00 |
Tube furnace Carbolite TF1 12/125/600 with 1 zone not split, temperature range 400 to 1200°C, heated tube length 600mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TF1121250600-230SN
Tube furnace Carbolite TF1 12/125/600 with 1 zone not split, temperature range 400 to 1200°C, heated tube length 600mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TF112/125/600 | 1 | No | 400 | 1200 | 600 | 125 | £6832.00 |
Tube furnace Carbolite TS1 12/60/300 split tube with 1 zone, temperature range 400 to 1200°C, heated tube length 300mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TS1120600300-230SN
Tube furnace Carbolite TS1 12/60/300 split tube with 1 zone, temperature range 400 to 1200°C, heated tube length 300mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TS112/60/300 | 1 | Yes | 400 | 1200 | 300 | 60 | £7134.00 |
Tube furnace Carbolite TS1 12/60/450 split tube with 1 zone, temperature range 400 to 1200°C, heated tube length 450mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TS1120600450-230SN
Tube furnace Carbolite TS1 12/60/450 split tube with 1 zone, temperature range 400 to 1200°C, heated tube length 450mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TS112/60/450 | 1 | Yes | 400 | 1200 | 450 | 60 | £7734.00 |
Tube furnace Carbolite TF1 12/125/800 with 1 zone not split, temperature range 400 to 1200°C, heated tube length 800mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 16Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TF1121250800-230SN
Tube furnace Carbolite TF1 12/125/800 with 1 zone not split, temperature range 400 to 1200°C, heated tube length 800mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 16Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TF112/125/800 | 1 | No | 400 | 1200 | 800 | 125 | £8012.00 |
Tube furnace Carbolite TS1 12/60/600 split tube with 1 zone, temperature range 600 to 1200°C, heated tube length 600mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TS1120600600-230SN
Tube furnace Carbolite TS1 12/60/600 split tube with 1 zone, temperature range 600 to 1200°C, heated tube length 600mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TS112/60/600 | 1 | Yes | 600 | 1200 | 600 | 60 | £8356.00 |
Tube furnace Carbolite TF1 16/60/180 with 1 zone not split, temperature range 600 to 1600°C, heated tube length 180mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 16Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TF1160600180-230SN
Tube furnace Carbolite TF1 16/60/180 with 1 zone not split, temperature range 600 to 1600°C, heated tube length 180mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 16Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TF116/60/180 | 1 | No | 600 | 1600 | 180 | 60 | £8515.00 |
Tube furnace Carbolite TS1 12/125/400 split tube with 1 zone, temperature range 400 to 1200°C, heated tube length 400mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TS1121250400-230SN
Tube furnace Carbolite TS1 12/125/400 split tube with 1 zone, temperature range 400 to 1200°C, heated tube length 400mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TS112/125/400 | 1 | Yes | 400 | 1200 | 400 | 125 | £8556.00 |
Tube furnace Carbolite TF3 12/60/600 with 3 zones not split, temperature range 400 to 1200°C, heated tube length 600mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, touch screen and remote control, requires work tube to be pruchased separately ![]() |
TF3120600600-230SN
Tube furnace Carbolite TF3 12/60/600 with 3 zones not split, temperature range 400 to 1200°C, heated tube length 600mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, touch screen and remote control, requires work tube to be pruchased separately |
Carbolite | TF312/60/600 | 3 | No | 400 | 1200 | 600 | 60 | £8790.00 |
Tube furnace Carbolite TF1 12/125/1000 with 1 zone not split, temperature range 400 to 1200°C, heated tube length 1000mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 20Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TF1121251000-230SN
Tube furnace Carbolite TF1 12/125/1000 with 1 zone not split, temperature range 400 to 1200°C, heated tube length 1000mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 20Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TF112/125/1000 | 1 | No | 400 | 1200 | 1000 | 125 | £9165.00 |
Tube furnace Carbolite TS1 12/125/600 split tube with 1 zone, temperature range 400 to 1200°C, heated tube length 600mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TS1121250600-230SN
Tube furnace Carbolite TS1 12/125/600 split tube with 1 zone, temperature range 400 to 1200°C, heated tube length 600mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TS112/125/600 | 1 | Yes | 400 | 1200 | 600 | 125 | £9460.00 |
Tube furnace Carbolite TF3 12/125/600 with 3 zones not split, temperature range 600 to 1200°C, heated tube length 600mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 13Amps, touch screen and remote control, requires work tube to be pruchased separately ![]() |
TF3121250600-230SN
Tube furnace Carbolite TF3 12/125/600 with 3 zones not split, temperature range 600 to 1200°C, heated tube length 600mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 13Amps, touch screen and remote control, requires work tube to be pruchased separately |
Carbolite | TF312/125/600 | 3 | No | 600 | 1200 | 600 | 125 | £10273.00 |
Tube furnace Carbolite TF1 12/125/1200 with 1 zone not split, temperature range 400 to 1200°C, heated tube length 1200mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 50Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TF1121251200-230SN
Tube furnace Carbolite TF1 12/125/1200 with 1 zone not split, temperature range 400 to 1200°C, heated tube length 1200mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 50Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TF112/125/1200 | 1 | No | 400 | 1200 | 1200 | 125 | £10344.00 |
Tube furnace Carbolite TG2 12/125/425 with 2 zones split, temperature range 400 to 1200°C, heated tube length 425mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be purchased separately ![]() |
TG2121250425-230SN
Tube furnace Carbolite TG2 12/125/425 with 2 zones split, temperature range 400 to 1200°C, heated tube length 425mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be purchased separately |
Carbolite | TG212/125/425 | 2 | Yes | 400 | 1200 | 425 | 125 | £10586.00 |
Tube furnace Carbolite TS1 12/125/800 split tube with 1 zone, temperature range 400 to 1200°C, heated tube length 800mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 16Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TS1121250800-230SN
Tube furnace Carbolite TS1 12/125/800 split tube with 1 zone, temperature range 400 to 1200°C, heated tube length 800mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 16Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TS112/125/800 | 1 | Yes | 400 | 1200 | 800 | 125 | £10750.00 |
Tube furnace Carbolite TS3 12/60/450 split tube with 3 zones, temperature range 600 to 1200°C, heated tube length 450mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, touch screen and remote control, requires work tube to be pruchased separately ![]() |
TS3120600450-230SN
Tube furnace Carbolite TS3 12/60/450 split tube with 3 zones, temperature range 600 to 1200°C, heated tube length 450mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, touch screen and remote control, requires work tube to be pruchased separately |
Carbolite | TS312/60/450 | 3 | Yes | 400 | 1200 | 450 | 60 | £11287.00 |
Tube furnace Carbolite TF3 12/125/800 with 3 zones not split, temperature range 400 to 1200°C, heated tube length 800mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 16Amps, touch screen and remote control, requires work tube to be pruchased separately ![]() |
TF3121250800-230SN
Tube furnace Carbolite TF3 12/125/800 with 3 zones not split, temperature range 400 to 1200°C, heated tube length 800mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 16Amps, touch screen and remote control, requires work tube to be pruchased separately |
Carbolite | TF312/125/800 | 3 | No | 400 | 1200 | 800 | 125 | £11425.00 |
Tube furnace Carbolite TS3 12/60/600 split tube with 3 zones, temperature range 400 to 1200°C, heated tube length 600mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, touch screen and remote control, requires work tube to be pruchased separately ![]() |
TS3120600600-230SN
Tube furnace Carbolite TS3 12/60/600 split tube with 3 zones, temperature range 400 to 1200°C, heated tube length 600mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, touch screen and remote control, requires work tube to be pruchased separately |
Carbolite | TS312/60/600 | 3 | Yes | 400 | 1200 | 600 | 60 | £11931.00 |
Tube furnace Carbolite TS1 12/125/1000 split tube with 1 zone, temperature range 400 to 1200°C, heated tube length 1000mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 20Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TS1121251000-230SN
Tube furnace Carbolite TS1 12/125/1000 split tube with 1 zone, temperature range 400 to 1200°C, heated tube length 1000mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 20Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TS112/125/1000 | 1 | Yes | 400 | 1200 | 1000 | 125 | £12014.00 |
Tube furnace Carbolite TG3 12/60/600 with 3 zones split, temperature range 400 to 1200°C, heated tube length 600mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TG3120600600-230SN
Tube furnace Carbolite TG3 12/60/600 with 3 zones split, temperature range 400 to 1200°C, heated tube length 600mm, can accommodate tubes up to 60mm diameter, single phase, 230volts, 13Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TG312/60/600 | 3 | Yes | 400 | 1200 | 600 | 60 | £12193.00 |
Tube furnace Carbolite TS1 12/200/600 split tube with 1 zone, temperature range 400 to 1200°C, heated tube length 600mm, can accommodate tubes up to 200mm diameter, single phase, 230volts, 40Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TS1122000600-230SN
Tube furnace Carbolite TS1 12/200/600 split tube with 1 zone, temperature range 400 to 1200°C, heated tube length 600mm, can accommodate tubes up to 200mm diameter, single phase, 230volts, 40Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TS112/200/600 | 1 | Yes | 400 | 1200 | 600 | 200 | £12316.00 |
Tube furnace Carbolite TF3 12/125/1000 with 3 zones not split, temperature range 400 to 1200°C, heated tube length 1000mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 20Amps, touch screen and remote control, requires work tube to be pruchased separately ![]() |
TF3121251000-230SN
Tube furnace Carbolite TF3 12/125/1000 with 3 zones not split, temperature range 400 to 1200°C, heated tube length 1000mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 20Amps, touch screen and remote control, requires work tube to be pruchased separately |
Carbolite | TF312/125/1000 | 3 | No | 400 | 1200 | 1000 | 125 | £12600.00 |
Tube furnace Carbolite TS1 12/125/1200 split tube with 1 zone, temperature range 400 to 1200°C, heated tube length 1200mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 25Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TS1121251200-230SN
Tube furnace Carbolite TS1 12/125/1200 split tube with 1 zone, temperature range 400 to 1200°C, heated tube length 1200mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 25Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TS112/125/1200 | 1 | Yes | 400 | 1200 | 1200 | 125 | £13294.00 |
Tube furnace Carbolite TF1 16/100/450 with 1 zone not split, temperature range 600 to 1600°C, heated tube length 450mm, can accommodate tubes up to 100mm diameter, single phase, 230volts, 40Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TF1161000450-230SN
Tube furnace Carbolite TF1 16/100/450 with 1 zone not split, temperature range 600 to 1600°C, heated tube length 450mm, can accommodate tubes up to 100mm diameter, single phase, 230volts, 40Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TF116/100/450 | 1 | No | 600 | 1600 | 450 | 100 | £13360.00 |
Tube furnace Carbolite TS3 12/125/600 split tube with 3 zones, temperature range 400 to 1200°C, heated tube length 600mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 13Amps, touch screen and remote control, requires work tube to be purchased separately ![]() |
TS3121250600-230SN
Tube furnace Carbolite TS3 12/125/600 split tube with 3 zones, temperature range 400 to 1200°C, heated tube length 600mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 13Amps, touch screen and remote control, requires work tube to be purchased separately |
Carbolite | TS312/125/600 | 3 | Yes | 400 | 1200 | 600 | 125 | £13410.00 |
Tube furnace Carbolite TF3 12/125/1200 with 3 zones not split, temperature range 400 to 1200°C, heated tube length 1200mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 25Amps, touch screen and remote control, requires work tube to be pruchased separately ![]() |
TF3121251200-230SN
Tube furnace Carbolite TF3 12/125/1200 with 3 zones not split, temperature range 400 to 1200°C, heated tube length 1200mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 25Amps, touch screen and remote control, requires work tube to be pruchased separately |
Carbolite | TF312/125/1200 | 3 | No | 400 | 1200 | 1200 | 125 | £13764.00 |
Tube furnace Carbolite TS3 12/125/800 split tube with 3 zones, temperature range 400 to 1200°C, heated tube length 800mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 16Amps, touch screen and remote control, requires work tube to be purchased separately ![]() |
TS3121250800-230SN
Tube furnace Carbolite TS3 12/125/800 split tube with 3 zones, temperature range 400 to 1200°C, heated tube length 800mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 16Amps, touch screen and remote control, requires work tube to be purchased separately |
Carbolite | TS312/125/800 | 3 | Yes | 400 | 1200 | 800 | 125 | £14754.00 |
Tube furnace Carbolite TS1 12/200/1200 split tube with 1 zone, temperature range 600 to 1200°C, heated tube length 1200mm, can accommodate tubes up to 200mm diameter, triple phase, 400volts, 25Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TS1122001200-230TX
Tube furnace Carbolite TS1 12/200/1200 split tube with 1 zone, temperature range 600 to 1200°C, heated tube length 1200mm, can accommodate tubes up to 200mm diameter, triple phase, 400volts, 25Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TS112/200/1200 | 1 | Yes | 600 | 1200 | 1200 | 200 | £15209.00 |
Tube furnace Carbolite TS3 12/200/600 split tube with 3 zones, temperature range 400 to 1200°C, heated tube length 600mm, can accommodate tubes up to 200mm diameter, single phase, 230volts, 40Amps, touch screen and remote control, requires work tube to be purchased separately ![]() |
TS3122000600-230SN
Tube furnace Carbolite TS3 12/200/600 split tube with 3 zones, temperature range 400 to 1200°C, heated tube length 600mm, can accommodate tubes up to 200mm diameter, single phase, 230volts, 40Amps, touch screen and remote control, requires work tube to be purchased separately |
Carbolite | TS312/200/600 | 3 | Yes | 400 | 1200 | 600 | 200 | £15747.00 |
Tube furnace Carbolite TS3 12/125/1000 split tube with 3 zones, temperature range 600 to 1200°C, heated tube length 1000mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 20Amps, touch screen and remote control, requires work tube to be pruchased separately ![]() |
TS3121251000-230SN
Tube furnace Carbolite TS3 12/125/1000 split tube with 3 zones, temperature range 600 to 1200°C, heated tube length 1000mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 20Amps, touch screen and remote control, requires work tube to be pruchased separately |
Carbolite | TS312/125/1000 | 3 | Yes | 600 | 1200 | 1000 | 125 | £16104.00 |
Tube furnace Carbolite TF1 16/100/600 with 1 zone not split, temperature range 600 to 1600°C, heated tube length 600mm, can accommodate tubes up to 100mm diameter, single phase, 230volts, 50Amps, no touch screen, with remote control, requires work tube to be pruchased separately ![]() |
TF1161000600-230SN
Tube furnace Carbolite TF1 16/100/600 with 1 zone not split, temperature range 600 to 1600°C, heated tube length 600mm, can accommodate tubes up to 100mm diameter, single phase, 230volts, 50Amps, no touch screen, with remote control, requires work tube to be pruchased separately |
Carbolite | TF116/100/600 | 1 | No | 600 | 1600 | 600 | 100 | £16178.00 |
Tube furnace Carbolite TS3 12/125/1200 split tube with 3 zones, temperature range 400 to 1200°C, heated tube length 1200mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 25Amps, touch screen and remote control, requires work tube to be purchased separately ![]() |
TS3121251200-230SN
Tube furnace Carbolite TS3 12/125/1200 split tube with 3 zones, temperature range 400 to 1200°C, heated tube length 1200mm, can accommodate tubes up to 125mm diameter, single phase, 230volts, 25Amps, touch screen and remote control, requires work tube to be purchased separately |
Carbolite | TS312/125/1200 | 3 | Yes | 600 | 1200 | 1200 | 125 | £17443.00 |
Tube furnace Carbolite TS3 12/200/1200 split tube with 3 zones, temperature range 600 to 1200°C, heated tube length 1200mm, can accommodate tubes up to 200mm diameter, triple phase, 400volts, 25Amps, touch screen and remote control, requires work tube to be pruchased separately ![]() |
TS3122001200-230TX
Tube furnace Carbolite TS3 12/200/1200 split tube with 3 zones, temperature range 600 to 1200°C, heated tube length 1200mm, can accommodate tubes up to 200mm diameter, triple phase, 400volts, 25Amps, touch screen and remote control, requires work tube to be pruchased separately |
Carbolite | TS312/200/1200 | 3 | Yes | 600 | 1200 | 1200 | 200 | £18634.00 |