Autoclaves - Rodwell - Sapphire 440E

To obtain best pricing, request a quotation for the Rodwell Sapphire 440E

Image


Catalogue no.


Description


Warranty (months) ? Brochure ? Average delivery time (weeks) ? List price


Offer price ? Quantity


SAP86 Autoclave Rodwell Sapphire 440E user programmable, suitable for liquids, no vacuum air removal, no autofill, 440l capacity, usable width 670mm, usable height 670mm, usable depth 848mm, no data output 12 months Rodwell_Autoclave_Sapphire_Direct_Steam_and_Electric.pdf ? £42501.12 £39236.00


This product is approved by the UK public sector under framework LAB5028 LU and is currently being evaluated for agreement LAB1021 AP. Further details can be obtained by searching the internet on "General Laboratory Equipment LAB5028 LU".

Environmental Performance

Location of Manufacturer UK

Additional information

Application Laboratory
Type Floor standing
Capacity 440 l
Suitable for liquids? Yes
User program-mable Yes
Loading Front
Autofill No
Vacuum air removal Optional
Number of chambers 1
Heat source required No
Chamber shape Rectangular
Usable width 670 mm
Usable height 670 mm
Usable depth 848 mm
Usable diameter 0 mm
Heating method Electric steam generator
Max run temperature 138 °C
Automatic door opening No
Sliding door Yes
Temperature and pressure gauges included Yes
Data output Optional - see accessories
Manual

No manual is currently available for this item.

Click here to request more details.



Accessories

AC260B Air ballasting

? £1435.20 £1351.33

AC426 Air filter Rodwell bacterial, for air ballast, 0.01µm (clean air only)

? £880.29 £837.03

AC266 Carbon filter kit Rodwell air ballasting

? £880.29 £837.03

AC260C Compressor for Air ballasting

? £1889.22 £1777.52

AC259 Condensate Retention boiler mod.

? £2194.42 £1980.60

AC430 Discard system NHS Standard HTM2010 Discard Container Sapphire

? £365.74 £333.44

AC110 Drain line condenser

? £915.60 £870.61

AC256 Dry Steam Option

? £844.98 £803.46

AC251 Float Level switch

? £829.84 £789.06

AC700 Full Liquid Ring System

? £5067.34 £4786.03

AC385  Keypad

? £210.57 £200.93

AC140 Load validation port Allows for the temporary fitting of up to 12 thermocouples

? £451.50 £418.69

AC87B Loading Trolley

? £1990.11 £1892.31

AC87 Loading Trolley

? £3856.63 £3667.11

AC806 Post Cycle Heat Drying

? £739.04 £702.72

AC255 Scale Prevention

? £205.99 £196.63

AC254 Scale Prevention

? £401.05 £381.34

AC264 Scale Prevention

? £993.79 £944.95

SBB4 Separate steam generator Integrated 24kw 14 Pre-heated boil

? £5602.08 £5326.78

SRB8 Separate steam generator Stand alone boiler for Sapphire 440

? £6106.54 £5806.45

AC330 Separate steam generator Switch valves for dual steam supply

? £1011.45 £961.74

AC95A Shelves

? £345.56 £328.57

TRB3 Stainless Steel Parts

? £4058.42 £3858.98

AC383  Standard Barcode Reader

? £385.92 £366.96

AC98A Transfer carriage for trolley

? £1727.79 £1617.07

AC240 Trays with lids

? £401.05 £373.56

AC180 USB memory logger consists of USB port Rodwell USB key and R

? £1135.04 £1079.26

AC702 Vacuum break + filter

? £224.29 £205.12

AC702B Vacuum break + filter

? £577.61 £549.22

AC702A Vacuum break + filter

? £322.86 £295.83

AC384   Wireless Barcode Reader

? £517.08 £491.67






Help / Quotation Request Form

Please fill in the boxes below to request help from a technical specialist.

Your email address:
Telephone number:
Name:
Company:
Type of equipment:
Your message



Contact - Maintenance and Repair

Please provide the following contact information and complete as many fields as possible. Alternatively call our Service Team on 01759 301142 and select option 3.

Your email address:
Telephone number:
Fax number:
Name:
Company:
I am looking for:
Type of equipment:
Manufacturer(s):
Number of units:
Catalogue Number:
Model Number:
Serial Number(s):
Comments



LAB1021 AP framework - SAP86

This product is currently being evaluated for framework agreement LAB1021 AP as it has the following minimum requirements.
  • The chamber to be constructed from high-grade stainless steel conforming to PD5500:2009 as amended
  • The general design, construction, operation and performance should conform to BS2646-1:1993 as amended.
  • Capable of generating its own steam electrically.
  • Chamber access via a door fitted with a safety mechanism that allows any residual pressure in the chamber to vent safely before the door can be opened fully.
  • Control panel, incorporating a chamber pressure gauge, allowing the user to select appropriate sterilisation cycles and monitor the progress of the sterilisation cycle via a digital/graphical display.
  • A minimum of 4 user selectable cycle programmes held in the autoclaves memory
  • The facility to lock cycle settings to prevent inadvertent changes to the settings by infrequent users. A key or PIN accessed supervisor mode would be necessary to set the parameters for the cycles.
  • User adjustable sterilisation temperatures in the range 100oC to 137oC. User adjustable sterilisation times, activated by the achievement of the preset sterilisation temperature, in the range of 1 – 60 minutes.
  • User adjustable free-steaming time in the range of 0 – 30 minutes
  • A thermal lock, with key override, on the chamber door that prevents opening before the chamber and goods cool to 80oC