Astell Scientific - Swiftlock

Stock Code: ASB270

Autoclave Astell Scientific Swiftlock user programmable, suitable for liquids, no vacuum air removal, no autofill, 153l capacity, usable depth 862mm, usable diameter 454mm, data logger included (replaces ASB270BT)

read more

List Price: Offer Price: Quantity:
£20,788.00 £18,194.00
List Price: £20,788.00
Offer Price: £18,194.00
Quantity:
Manufactured in uk1 Year WarrantyDelivery Time

Autoclave Astell Scientific Swiftlock user programmable, suitable for liquids, no vacuum air removal, no autofill, 153l capacity, usable depth 862mm, usable diameter 454mm, data logger included (replaces ASB270BT)


Power Draw:10.00kW
Type:Floor standing
Capacity:153l
Suitable for liquids?:Yes
User programmable:Yes
Loading:Front
Autofill:Optional
Vacuum air removal:Optional
Number of chambers:1
Heat source required:No
Chamber shape:Round
Usable width:0mm
Usable height:0mm
Usable depth:862mm
Usable diameter:454mm
Heating method:Electric (in chamber)
Max run temperature:138°C
Automatic door opening:No
Sliding door:No
Temperature and pressure gauges included:Yes
Data output:Data logger
Disinfection type:Steam
Assisted air cooling:Optional
Suitable for laboratory use:Yes
Suitable for dental use:No
Suitable for medical use:No
Suitable for beauty/tattoo use:No

Minimum specification that this product meets

  • The chamber to be constructed from high-grade stainless steel conforming to PD5500:2009 as amended
  • The general design, construction, operation and performance should conform to BS2646-1:1993 as amended.
  • Capable of generating its own steam electrically.
  • Chamber access via a door fitted with a safety mechanism that allows any residual pressure in the chamber to vent safely before the door can be opened fully.
  • Control panel, incorporating a chamber pressure gauge, allowing the user to select appropriate sterilisation cycles and monitor the progress of the sterilisation cycle via a digital/graphical display.
  • A minimum of 4 user selectable cycle programmes held in the autoclaves memory
  • The facility to lock cycle settings to prevent inadvertent changes to the settings by infrequent users. A key or PIN accessed supervisor mode would be necessary to set the parameters for the cycles.
  • User adjustable sterilisation temperatures in the range 100oC to 137oC. User adjustable sterilisation times, activated by the achievement of the preset sterilisation temperature, in the range of 1
  • 60 minutes.
  • User adjustable free-steaming time in the range of 0
  • 30 minutes
  • A thermal lock, with key override, on the chamber door that prevents opening before the chamber and goods cool to 80oC