Free Delivery to UK Mainland

UV-1900i

207-25700-58-PACKAGE

10437161
9856.00

Overview

Spectrophotometer Shimadzu UV-1900i 190-1100nm wavelength, bandwidth 1nm, scanning, dual beam, for general purpose, DNA/RNA, educational, life science, industrial, micro volume and pharmaceutical applications, single cell holder, includes touch panel (228-59212-41) and power cable (980-24241). Note that these units need installing by a Shimadzu engineer in order to validate the warranty. Please use part number INSTALLATION-UV (Replaces part number 207-23100-58)

£9856.00

Free Standard Delivery to Mainland UK

Estimated 6 Weeks

Manufactured outside the EU

1 Year Warranty

Standard warranty covers parts and labour for material and manufacturing defects. Extended warranties are available on request.

Download Product Brochure

Part Number Description List Price Offer Price
Installation Shimadzu UV Installation-UV

Installation Shimadzu UV

Popular Accessory

£1,298.00

£1,298.00

6-cell positioner Shimadzu CPS-100 thermoelectrically temperature controlled, used in Kinetics mode, this provides measurement of up to 6 temperature-sensitive enzyme samples. Number of cells: 6 on the sample side (temperature-controlled), 1 on the reference side (temperature not controlled). 206-29500-58

6-cell positioner Shimadzu CPS-100 thermoelectrically temperature controlled, used in Kinetics mode, this provides measurement of up to 6 temperature-sensitive enzyme samples. Number of cells: 6 on the sample side (temperature-controlled), 1 on the reference side (temperature not controlled).

£6,104.00

£6,104.00

Automatic 6-cell holder 206-69160-41

Automatic 6-cell holder

£811.00

£811.00

Cell holder Shimadzu TCC-100, thermoelectrically temperature controlled, single-cell peltier. Number of cells: One each on the sample and reference sides (Peltier temperature-controlled). 206-29510-58

Cell holder Shimadzu TCC-100, thermoelectrically temperature controlled, single-cell peltier. Number of cells: One each on the sample and reference sides (Peltier temperature-controlled).

£3,968.00

£3,968.00

Cell Holder Shimzadzu constant temperature four-cell holder. Four 10mm Pathlength Sample and one Reference Cell maintained at Temperature range of 5°C to 90°C, according to selection of water recirculator system  (optional purchase of PCB-1500 P/N 980-09081). Water pipe connectors: 9 mm. Note: The Four-Cell Sample Compartment Unit (P/N 206-23670-91) is necessary. 204-27206-02

Cell Holder Shimzadzu constant temperature four-cell holder. Four 10mm Pathlength Sample and one Reference Cell maintained at Temperature range of 5°C to 90°C, according to selection of water recirculator system (optional purchase of PCB-1500 P/N 980-09081). Water pipe connectors: 9 mm. Note: The Four-Cell Sample Compartment Unit (P/N 206-23670-91) is necessary.

£2,394.00

£2,394.00

Cell Holder Shimzadzu long-path, rectangular, holds two rectangular cells with an optical path length of 10, 20, 30, 50, 70, or 100 mm. 204-23118-01

Cell Holder Shimzadzu long-path, rectangular, holds two rectangular cells with an optical path length of 10, 20, 30, 50, 70, or 100 mm.

£1,000.00

£1,000.00

Cell Holder Shimzadzu reference-side, rectangular, long-path, absorption. Note: Requires the Four-Cell Sample Compartment unit (P/N 206-23670-91). 204-28720

Cell Holder Shimzadzu reference-side, rectangular, long-path, absorption. Note: Requires the Four-Cell Sample Compartment unit (P/N 206-23670-91).

£585.00

£585.00

Cell Holder Shimzadzu universal, rectangular, four-cell type. Holds four rectangular cells with an optical path length of 10, 20, 30, 50, 70, or 100 mm. Note: Requires the Four-Cell Sample Compartment unit (P/N 206-23670-91). When a rectangular, long-path cell is used on the reference side, its holder (P/N 204-28720) is also required. 204-27208

Cell Holder Shimzadzu universal, rectangular, four-cell type. Holds four rectangular cells with an optical path length of 10, 20, 30, 50, 70, or 100 mm. Note: Requires the Four-Cell Sample Compartment unit (P/N 206-23670-91). When a rectangular, long-path cell is used on the reference side, its holder (P/N 204-28720) is also required.

£680.00

£680.00

Film holder Shimzadzu used in transmittance measurement of thin samples such as films and filters. Sample Size Mimimum: 16 (W) × 32 (H) mm. Sample Size Maximum: 80 (W) × 40 (H) × 20 (Thickness) mm 204-58909

Film holder Shimzadzu used in transmittance measurement of thin samples such as films and filters. Sample Size Mimimum: 16 (W) × 32 (H) mm. Sample Size Maximum: 80 (W) × 40 (H) × 20 (Thickness) mm

£328.00

£328.00

Sample compartment unit Shimadzu four-cell, accommodates four square cross-section 10mm pathlength cuvettes in the sample beam, and one similar cuvette in the reference beam.  Manual Change of position settings. Note: There is no temperature control capability with this unit. Cuvettes not included. 206-23670-91

Sample compartment unit Shimadzu four-cell, accommodates four square cross-section 10mm pathlength cuvettes in the sample beam, and one similar cuvette in the reference beam. Manual Change of position settings. Note: There is no temperature control capability with this unit. Cuvettes not included.

£1,413.00

£1,413.00

Test tube holder Shimzadzu outside diameter: 15 to 18 mm. Height: 84 to 115 mm Note: Test tube is not included. 207-23510-41

Test tube holder Shimzadzu outside diameter: 15 to 18 mm. Height: 84 to 115 mm Note: Test tube is not included.

£918.00

£918.00

Training Shimadzu half day by Shimadzu product specialist TRAINING-UV

Training Shimadzu half day by Shimadzu product specialist

£2,749.00

£2,749.00

Shimadzu UV-1900i

Spectrophotometer Shimadzu UV-1900i 190-1100nm wavelength, bandwidth 1nm, scanning, dual beam, for general purpose, DNA/RNA, educational, life science, industrial, micro volume and pharmaceutical applications, single cell holder, includes touch panel (228-59212-41) and power cable (980-24241). Note that these units need installing by a Shimadzu engineer in order to validate the warranty. Please use part number INSTALLATION-UV (Replaces part number 207-23100-58)

Min wavelength:
190
Max bandwidth:
1
Scanning:
Yes
Beam format:
Dual
Cell holders:
1
Max wavelength:
1100
Bluetooth:
No
Suitable for general purpose applications:
Yes
Suitable for DNA/RNA applications:
Yes
Suitable for educational applications:
Yes
Suitable for life science applications:
Yes
Suitable for industrial applications:
Yes
Suitable for micro volume applications:
Yes
Suitable for pharmaceutical applications:
Yes
Printer included:
No
Temperature controlled cuvette shaft? :
Optional
Min bandwidth:
1
Touch screen?:
Yes
Removable sample port:
No
No lid/moveable parts:
No