Grant Block Heaters
|
Prima
Series
The new
Prima series of microprocessor dry block heaters accommodate
samples in tubes, vials or slides for unrivalled versatility
over the range from just above ambient to 130ºC.
Six low
profile units have angled display panels and touch sensitive
keys for ease of operation, under a rugged waterproof membrane.
The
Prima range offers two models:
-UBD
cost effective digital block heaters
-UBR full feature models.
UBD /
UBR
 |
Models
for 1, 2 and 4 blocks |
 |
Small
footprint and low profile for practical access |
 |
Variety
of sample blocks for all applications - including tubes
and vials |
 |
Temperature
range ambient +5 to 130ºC, stability ± 0.1 at 70ºC. |
 |
Clear
4 digit angled LCD display / keypad enables easy setup
from standing position |
 |
Fast
heat-up - 16 minutes to 100ºC |
 |
Optional
external sensors for in-block control |
 |
Auto
2 point calibration facility |
In
addition the UBR offers
 |
In
built timer |
 |
Time
saving programmable delayed start |
 |
RS-232
output provides data monitoring facility |
| The
UBD and UBR's are available in 1,2, and 4 block versions |
 |
|
|
|
No.of
blocks
|
|
|
|
UBD1
|
UBR1
|
1
|
|
|
|
UBD2
|
UBR2
|
2
|
|
|
|
UBD4
|
UBR4
|
4
|
 |
|
|
  |
| Specification |
|
|
|
UBD1/R1 |
UBD2/R2 |
UBD4/R4 |
  |
| Temperature
range |
|
ºC |
ambient+5
to 130 |
ambient+5
to 130 |
ambient+5
to 130 |
  |
| Stability |
|
ºC |
±
0.1 @ 70 |
±
0.1 @ 70 |
±
0.1 @ 70 |
  |
| Uniformity
well to well |
|
ºC |
±
0.1 @ 70 |
±
0.1 @ 70 |
±
0.1 @ 70 |
  |
| Heat-up
speed |
25
to 100 |
ºC |
16
minutes |
16
minutes |
16
minutes |
  |
| Dimensions |
w/d/h |
mm |
215/220/75 |
215/300/75 |
315/300/75 |
  |
| Weight
excluding blocks |
|
kg |
1.8 |
2.2 |
3.6 |
  |
| Power |
|
|
230v
A/C 150w |
230v
A/C 150w |
230v
A/C 150w |
  |
|
Accessories
Prima UB
Block Heaters use interchangeable blocks that can accommodate
test tubes, universal bottles, microcentrifuge tubes and
microplates.

|
 |
| Order
ref: |
Tube
type |
Holes
per block
|
| BB-0 |
plain |
0
|
| BB-6 |
6mm |
35
|
| BB-10 |
10mm |
20
|
| BB-13 |
13mm |
20
|
| BB-16 |
16mm |
12
|
| BB-18 |
18mm |
6
|
| BB-24 |
24mm |
6
|
| BB-50 |
50mm |
4
|
| BB-E1 |
1.5ml
microfuge |
24
|
| BB-E0 |
0.5ml
microfuge |
24
|
| BB-DN |
1.5mm
microtubes,
dolphin nose |
24
|
| BB-MT |
combination
block: |
|
| |
25mm |
3
|
| |
13mm |
5
|
| |
6mm |
6
|
| BB-HS |
microscope
slides
horizontal |
8
|
| BB-SS |
microscope
slides
45º angle |
5
|
| BB-CV |
cuvettes |
15
|
| |
|
|
| Block
dimensions: |
|
| Standard |
76
x 95 x 51mm |
|
 |
| UBEP: |
External
probe |
|
 |
|
Equipment
safety
Prima
block heaters meet the requirements of IEC61010 parts 1 and 2.
CE mark
The Prima series block heaters bear a CE mark to indicate that they meet
the requirements of the Low Voltage and EMC Directives.
After sales
service
In the United Kingdom, repairs are normally carried out within two
working days of arrival at our factory or receipt of authorisation to
repair. Alternatively, spare parts and service manuals can be despatched
within two working days.
Most overseas
distributors of Grant equipment hold stocks of spare parts, have their
own service engineers and operate a similarly prompt repair service.
Three year
guarantee
Prima series block heaters are robust and reliable, designed and built
to provide you with years of trouble-free service.
They are
guaranteed for three years against faulty materials and workmanship. If
repairs are carried out under guarantee, no charge is made for labour or
materials, and within the UK we make no charge for return carriage.
We are committed
to a continuous programme of improvement and specifications may be
charged without notice.
|
|



|
|
Health
and Safety Regulations dictate that increasing amounts of work are
carried out in a fume hood or safety cabinet; block heaters provide the
ideal solution to the problem of achieving accessible,
contamination-free temperature control within the fume hood itself.
Block heater
|
using
aluminium as the temperature transfer medium, for dry heating of
samples |
Convenient dry
temperature control
 |
easily
carried and spill-proof - ideal for carrying vessels from place
to place (not BT5D) |
 |
safe
operation at high temperatures without the need to use oil |
 |
the
laboratory remains steam-free during high temperature procedures |
Design features
 |
designed to take up
as little space as possible on the bench or in a fume hood |
 |
Grant
block heaters are robust and reliable, to stand up to everyday
wear and tear |
BBA analogue block
heater
Ambient + 5°C to 130°C operation
Stability ±0.5°C
 |
for
consistent long-term temperature control |
Fast heat up rate
Analogue setting
 |
easy-to-use,
conventional knob and dial; a reference thermometer will be
necessary for accurate temperature setting |
Interchangeable
blocks: 1, 2 or 4
 |
choice of
models available to accommodate 1, 2 or 4 aluminium blocks per
unit |
 |
choice of
blocks available to suit a wide range of tube sizes |
Safety
 |
overtemperature
protection by thermal fuse |
|



|

|
BT5D
high temperature block heater
Ambient + 10ºC to 400ºC
operation
Stability ± 0.5ºC
uniformity 1%
 |
for
consistent long term high temperature control |
Microprocessor
controller
features include:
 |
digital
temperature setting and display |
 |
high and
low alarms |
 |
controlled
heating rate, setting resolution 0.1ºC/minute |
 |
timed or
continuous operation; timer setting resolution 1 minute, maximum
period 9999 minutes |
Single fixed aluminium
block
 |
choice of
models available to suit two alternative tube sizes |
Safety
 |
adjustable
overtemperature cut-out |
Please specify the type of block you
require:
|
Order ref.
|
Tube Ø
mm
|
Holes
per block
|
Hole Ø
mm
|
Hole depth
mm
|
|
BT5D-16
|
16
|
38
|
16.5
|
60
|
|
BT5D-26
|
26
|
22
|
26.5
|
60
|
|
|